KNOW YOUR FLOW

A SIMPLE METHOD
THE DOSATRON IS COMPOSED OF:
2 clicks = 1 motor
cycle = The stroke
volume
The speed of the motor is proportional to the flow of water passing through
the system.
Calculation of water flow in l/h
n
Number of clicks in 15 seconds
2 clicks = 1 cycle
Calculation of water flow in GPM =
n
Number of clicks in 15 seconds
2 clicks = 1 cycle
NOTA :
This method of calculation cannot replace a flow meter. It is given
only as an approximate guide.
A driving
volumetric
hydraulic
motor piston
connected
to :
a dosing
piston.
=
2
2
©
©
DOSATRON INTERNATIONAL S.A.S / 59
DOSATRON INTERNATIONAL S.A.S / 59
In its up and down movement, you
can hear the motor piston click:
Once in the up
position
Calculation for 1 minute
x
4 x 60 x
Calculation for 1 hour
Calculation for 1 minute
x
4 x 0.53
Stroke volume in litres
Once in the
down position
Stroke volume
in litres
0.53
conversion litres
to gallons
3.8
÷