ATEX AND IECEX MARKING
0.2 to 2% [1:500 to 1:50]
Injection rate:
10 l/h to 3 m
Operating flow:
0.30 to 6 bar
Operating pressure:
Concentrated
0.2 l/h to 60 l/h
additive injection:
40°C
Maximum temperature:
EPL DEFINED INTO THE ISO 80079-36:2016 STANDARD
Equipment for explosive atmospheres is divided into:
a) Group I equipment for mines susceptible to firedamp; this group
comprises two EPLs: EPL Ma, EPL Mb ;
b) Group II Equipment for locations with an explosive atmosphere
caused by mixtures of air and gases, vapors or mists; this group comprises
three EPLs: EPL Ga, EPL Gb, EPL Gc ;
c) Group III Equipment for locations with an explosive atmosphere,
caused by mixtures of air and combustible dusts; this group comprises three
EPLs: EPL Da, EPL Db, EPL Dc.
1- Non electrical equipment in accordance with ISO 80079-36 :2016
and ISO 80079-37 :2016 for EPL (Equipment Protection Level) Ma
for use in explosive atmosphere presents inside mines susceptible
to firedamp.
2- Non electrical equipment in accordance with ISO 80079-36 :2016
and ISO 80079-37 :2016 for EPL (Equipment Protection Level)
Ga for use in explosive gas atmospheres of Group IIB and ignition
temperature greater than the temperature class T6 (85°C)
3- Non electrical equipment in accordance with ISO 80079-36 :2016
and ISO 80079-37 :2016 for EPL (Equipment Protection Level) Da
for explosive dust atmospheres containing dusts of Group IIIC and
maximum surface temperature less the temperature class T6 (85°C).
3
/h
Compliance with European Directives,
2014/34/UE for ATEX CE marking
Number of notified body delivering
the Quality Assurance Notification
©
DOSATRON INTERNATIONAL S.A.S / 39
IECEX Certification number
Number of UE Type
Examination Certificate
3
3
2
2
1
1
Ex h I Ma
Ex h IIB T6 Ga
Ex h IIIC T85°C Da
Warning : Potential danger of electrostatic loads
– See instructions on the owner manual.
Do not wipe the dispenser with a dry cloth.
DOSATRON INTERNATIONAL S.A.S - Rue Pascal. BP 6. 33370 TRESSES France
IECEx INE 16.0031X
Ineris 14ATEX0066X
I M1
II 1 GD
0080