DESCRIPTION OF ALARMS

These alarms occur when there is a defect on the machine, they are indicated differently depending
on the nature of the defect.
 ALARM TIME OUT 1ST FILLING
If the electronic does not receive information from the SN level probe for more than 360 seconds (at
the 1st filling), the LED "L2" & "L3" of all groups will flash to indicate failure.
 ALARM FLOWMETER
If, during the distribution of coffee, the mother board does not receive pulses from a flowmeter for
more than 4 seconds, all LEDs of the concerned group start flashing to indicate failure. After 45
seconds, the machine automatically stops the solenoid valve of the concerned coffee group and the
pump also.
 ALARM TEMPERATURE SENSOR DISCONNECTED
If the mother board does not receive information from the temperature sensor for more than 3
seconds, the electronics automatically cut off the solid state relay and leds "L1"& "L4" from all groups
will flash to indicate default.
 OVER TEMPERATURE ALARM
If the electronics detects a temperature > 140 °C for more than 5 seconds in the boiler, the LEDs
"L3" of all groups will flash at the same time and the management of the heating is stopped
automatically.The alarm is removed when the temperature drops below 125 ° C.
SACOME, CONFIDENTIAL Document,
Edition 07/2018 - CC100
TECHNICAL DOCUMENTS - page 40
it is forbidden to duplicate or communicate this document without previous authorization.

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cc101 iCc102 iCc103 iCc103 i tri

Table des Matières