Trouble Shooting - probst EXG-MAXI Instructions D'emploi

Pince de manutention pour plaques
Masquer les pouces Voir aussi pour EXG-MAXI:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance and care
7.3

Trouble shooting

ERROR
The clamping-power is not big enough,
the load is slipping out
(optional)
(optional)
(Adjustment of the gripping range)
(optional)
(Property of material)
Unbalanced load
(Adjustment of the gripping range)
(optional)
Automatic release does not work
mechanical
(optional)
CAUSE
The grippers are worn
The maximum load is exceed
The actual opening width is not
correct
The surface of the material is dirty
or the material is not suitable /
allowed for this device.
The device is not loaded
symmetrically
The adjustment of the gripping
range is not symmetrical.
Automatic release does not work
REPAIR
Replace the grippers
Reduce the weight of. the load
Adjust the gripping range
according to the load you want to
transport
Check the surface of the material
or ask the manufacturer, if you the
material is allowed for this device.
Adjust the position of the load
Correct the adjustment of the
gripping range
Clean automatic release with high
pressure-cleaner
Oil the automatic release (never
with grease)
Correct faulty switching (see
chapter "Picture of the automatic
release")
Change the inset of the automatic
release
16 / 18

Publicité

Table des Matières
loading

Table des Matières