Control unit CL2S
Product type
Adopted technology
Max. cycles frequency
Power supply
Absorbed rated power
Emergency power supply
Motor outputs
Flashing light output
ECSBus output
"OPEN" input
"STOP" input
Radio aerial input
Max. cable length
Ambient operating temperature
Use in particularly acid, saline or
potentially explosive atmospheres
Assembly
Protection rating
Dimensions / weight
Possibility of remote control
Compatible GTX4 transmitters
GTX4 transmitter range
Programmable functions
Self-programmed functions
26 – English
Control unit for 1 or 2 24Vdc motors for automation of automatic gates or doors, complete with
radio receiver for "GTX4" transmitters
Electronic board governed by 8-bit microcontroller with flash technology
A transformer incorporated in the control unit, but separated from the board, reduces the mains
voltage to the nominal 24 V voltage used in the whole automation system.
30 cycles/hour
230Vac (+10% -10%) 50/60Hz
120 W; on start-up power is 310 W for a maximum time interval of 2s
For "PR1" buffer batteries
2, for 24 Vdc motors with nominal current of 1.1A, on start-up, maximum current is 3.5 A for a
maximum time interval of 2 s
For flashing lights with 12V (maximum 21 W) bulb
1 output with maximum load of 15 ECSBus units
For normally open contacts (closure of the contact prompts the "OPEN" command)
For normally open and/or 8,2kohm constant resistance type contacts, or normally closed con-
tacts with self-learning of the "normal" status (a variation with respect to the memorised status
generates a "STOP" command)
50 ohm for RG58 or similar type cable
Mains power-supply: 30 m; motor outputs: 10 m; other inputs/outputs: 20 m with antenna cable
preferably less than 5 m (observe warnings regarding the minimum section and type of cables)
-20 ÷ 50°C
No
Vertical, wall-mounted
IP44
180 x 240 h 110mm / 2.8kg
With "GTX4" transmitters, the control unit is set to receive one or more of the following comman-
ds: "OPEN", "Partial opening", "Only Open" and "Only Close"
Up to 150 if memorised in mode 1
50-100 m This distance may vary in the presence of obstacles and electromagnetic disturbance
present, and is influenced by the position of the receiving antenna built into the flashing light
"Single cycle" or "Complete cycle" (automatic closure) operating mode
Motor speed "low" or "high"
Pause time in "complete cycle" selectable from 10, 20, 40, and 80 seconds
Type of partial opening selectable from 4 modes
Obstacle detection system sensitivity selectable on 4 levels "Open command" operating mode
selectable on 4 modes
Self-learning of devices connected to the ECSBus output
Self-learning of type of "STOP" device (NO, NC or 8.2 kΩ resistance contact)
Self-learning of manoeuvre length for each motor
Self-learning og the automation with 1 or 2 motors