7 Operation

6.6 Setting the shielding gas volume

6.7 Introducing the wire
7 Operation
EN - 14
NOTICE
• The type and amount of shielding gas used depend on the welding task
and the gas nozzle geometry.
• To prevent the shielding gas supply from becoming clogged by
impurities, the cylinder valve must be opened briefly before connecting
the cylinder. This will expel any impurities that may be present.
• Make all shielding gas connections gas-tight.
1 Connect the shielding gas cylinder to the wire feeder.
2 Set the gas quantity on the shielding gas cylinder's pressure reducer.
NOTICE
• Each time the wire is changed, make sure that the beginning of the wire is
free of burrs.
1 Insert the wire into the wire feeder as specified by the manufacturer.
2 Press the "Zero current wire feed" trigger on the wire feeder.
DANGER
Shortness of breath and poisoning caused by inhaling
phosgene gas
When welding workpieces that have been degreased with chlorinated
solvents, phosgene gas is formed.
• Rinse workpieces with clean water prior to welding.
• Do not inhale fumes and vapours.
• Ensure a sufficient supply of fresh air.
• Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
MIG/MAG ROBO welding torch