MF1-Laser Front/Rear
6.3.2 Setting the contact pressure
The contact pressure can be set between 0 and 225
1 Open the housing cover.
Fig. 9 Opening the housing cover on page EN-14
2 Swivel out the rocker arm.
Fig. 10 Swivel open the rocker arm on page EN-15
3 Set the contact pressure by turning the adjusting screw.
1
Fig. 14
Adjusting screw
Setting the contact pressure
±
40 N.
1
6 Commissioning
EN - 17