Télécharger Imprimer la page

Dometic COOLAIR SP 950C Instructions De Montage page 4

Masquer les pouces Voir aussi pour COOLAIR SP 950C:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Safety instructions
2
Safety instructions
2.1
Using the device
• The freedom of movement of semi-trailers (of the outer edges of the semi-trailer when turning or jackknifing)
and other vehicle attachments must not be restricted.
• Only use the air conditioning roof unit for the purpose specified by the manufacturer and do not make any alter-
ations or structural changes to the device.
• Do not use the air conditioning roof unit if it is visibly damaged.
• The air conditioning roof unit must be installed safely so that it cannot tip over or fall down.
• Installation, maintenance and repair work may only be carried out by qualified personnel from a specialist com-
pany who are familiar with the risks involved and the relevant regulations.
• Do not use the air conditioning roof unit near flammable fluids and gases.
• Do not operate the air conditioning roof unit if the ambient temperature is below 0 °C.
• Do not undo the upper cover of the air conditioning roof unit in the event of a fire. Use approved extinguishing
agents instead. Do not use water to extinguish fires.
• Disconnect all power supply lines when working on the air conditioning roof unit (cleaning, maintenance, etc).
2.2
Handling electrical cables
• Use cable ducts to lay cables through walls with sharp edges.
• Do not lay loose or bent cables next to electrically conductive materials (metal).
• Do not pull on the cables.
• Attach and lay the cables in such a manner that they cannot be tripped over or damaged.
• The electrical power supply may only be connected by a specialist workshop.
• Fit a fuse of 25 amps to the connection to the vehicle's power supply.
• Never lay power supply lines (battery leads) in the vicinity of signal or control cables.
3
Conventions in this manual
3.1
General information on the installation manual
This installation manual contains the essential information and instructions for installing the parking cooler. The
information is intended to be read by the installation personnel of the parking cooler.
The following instructions are intended to help you use the installation manual properly:
• The installation manual is part of the scope of delivery and should be stored carefully.
• The installation manual provides you with important information on the installation of the device and can also
be used as a reference material in the event of repairs.
• The manufacturer assumes no liability for non-observance of this installation manual. Any claims are excluded in
this case.
3.2
Target group
The installation and configuration information in this manual is intended for qualified installation personnel who are
familiar with the guidelines and safety precautions to be applied during the installation of lorry accessory parts.
4
Intended use
The CoolAir parking cooler is for supplying the cab of a lorry with cooled and dehumidified air. It can be used while
driving. It is not suitable for houses and appartments.
4
SP 950C, SPX 1200C
EN

Publicité

loading

Ce manuel est également adapté pour:

Coolair spx 1200c