RF 96 ST SW868/SW915/SW917/SW922
//
Montage- und Anschlussanleitung / Funkschalter
Mounting and wiring instructions / Wireless switch
Instructions de montage et de câblage / Interrupteur sans fil
Istruzioni di montaggio e collegamento / Interruttore wireless
Instruções de montagem e instalação / Interruptor de rádio frequência
Инструкция по монтажу и подключению / Радио-выключатель
English
Field strength meter for range test:
Transmitter
Device
SW868
swView 868 MHz
SW915
swView 915 MHz
SW917/SW922
Radio operation
The transmission of a switching command from the transmitter to the
receiver takes about 80 to 100 ms, based on the sWave ® data trans-
mission. The switching signal of a transmitter must not be generated
at a shorter distance, otherwise this signal will be overlooked. The re-
ceiver must support the sWave ® protocol of the steute modules. Each
switching operation triggers a transmission from the radio unit. This
also applies if several channels are activated or deactivated simulta-
neously. The current value of the battery voltage is transmitted with
each transmission.
Safety
Do not use the device in connection with other devices whose direct or
indirect purpose is to ensure life or health, or whose operation may
pose a threat to humans, animals or material assets.
Maintenance and cleaning
With rough conditions, we recommend routine maintenance as follows:
1. Removal of all dirt particles.
2. Remove dust from sensor surfaces.
Clean enclosure on the outside only. Clean enclosure with household
cleaning agents. Do not use compressed air to clean.
Battery
The remaining capacity of a battery is hard to evaluate, but an empty
battery can be assumed in case of doubt and with a battery voltage ap-
prox. <3.4 V at 20°C. In order to ensure reliable functioning, the battery
must be replaced. To do this, the 5 screws in the housing cover must
be opened using a torx-8 screwdriver. The battery should be inserted
in the direction shown by the symbols on the cover. Use only the desig-
nated battery type or a complementary battery type. Depending on the
country the device is supplied to, delivery will include an AA lithium
battery SL-760/3.6 V/2.2 Ah in a battery adapter, or a lithium battery
SL-2770/3.6 V/8.5 Ah without an adapter or a complementary battery
type.
Spare part:
Name
Lithium battery SL-2770/S 3.6 V/8.5 Ah
Lithium battery SL-760 (3.6 V/2.2 Ah AA)
Material No.
1190393
1221794
on request
Material No.
1202806
1351045
4 / 20
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately. Dispose of possibly contained
batteries correctly.
Status signal
A status signal can be set by the user at various intervals with the
jumper. To do this, open the enclosure by removing the 5 cover screws
using a Torx 8 screwdriver. Take care to ensure sufficient ESD protec-
tion. Inside the enclosure a jumper is located on the circuit board. Ad-
just to the desired interval. For evaluation of status signals, steute pro-
vides special receivers.
delivery state:
no status signal
Jumper
Intervall
without jumper
no status signal
or 1 and 2
Position 1
10 s
Position 2
100 s
Position 3
1,000 s
Position 4
10,000 s
After successful adjustment replace the enclosure cover and tighten
the cover screws with approx. 0.45 Nm. The sealing must not be con-
taminated by any foreign bodies.
N.B.
The electrical connection may only be carried out by authorised per-
sonnel. Subject to technical modifications. Reconstruction and altera-
tions to the device are not allowed. steute does not assume any liability
for recommendations made or implied by this description. New claims
for guarantee, warranty or liability cannot be hereby derived beyond
the general terms and conditions of delivery.
ESD
Ensure adequate ESD protection for all work that requires opening
the unit.
example position 1:
status signal every 10 s