Table Des Matières; General Safety Warnings And Precautions; Safety Warnings; Installation Warnings - Nice Moon MC824HR Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
ENGLISH
Contents
GENERAL SAFETY WARNINGS AND PRECAUTIONS. . . . . . . . . . . . . . . 1
Safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

1 - PRODUCT DESCRIPTION AND INTENDED USE . . . . . . . . . . . . . . . . 1
2 - INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 - Preliminary checks for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2 - Product application limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.3 - Typical system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.4 - Installation of control unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 - ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1 - Description of electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.2 - Electrical connections of MC824HR control unit . . . . . . . . . . . . . . . . . . 2
3.3 - Connection of other devices to MC824HR . . . . . . . . . . . . . . . . . . . . . . 3
3.5 - Initial start-up and electrical connections . . . . . . . . . . . . . . . . . . . . . . . . 3
3.6 - Learning of the devices connected to MC824HR . . . . . . . . . . . . . . . . . 3
3.7 - Mechanical limiter position learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.7.1 - Learning in automatic mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.7.2 - Learning in manual mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.7.3 - Learning in combined mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.8 - Checking movement of gate leafs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4 - TESTING AND COMMISSIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1 - Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.2 - Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5 - PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.1 - Level one programming (ON-OFF functions) . . . . . . . . . . . . . . . . . . . . . 5
5.2 - Level two programming (adjustable parameters) . . . . . . . . . . . . . . . . . . 6
5.3 - Special functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.4 - Deletion of memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 - WHAT TO DO IF... (troubleshooting guide) . . . . . . . . . . . . . . . . . . . . 8
7 - FURTHER DETAILS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7.1 - Connecting a radio receiver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7.2 - Connecting Oview programming unit. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7.3 - Connecting the Solemyo solar energy system . . . . . . . . . . . . . . . . . . . . 9
7.4 - Connecting model PS324 buffer battery . . . . . . . . . . . . . . . . . . . . . . . . 9
8 - PRODUCT MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PRODUCT DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
TECHNICAL CHARACTERISTICS OF THE PRODUCT . . . . . . . . . . . . . 10
CE DECLARATION OF CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
Instructions and warnings for the user . . . . . . . . . . . . . . . . . . . . . . . . . . V
Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XII

GENERAL SAFETY WARNINGS AND PRECAUTIONS

Safety warnings
• IMPORTANT! - This manual contains important instructions and warn-
ings for personal safety. Incorrect installation could cause serious physical
injury. Read all parts of the manual carefully before starting work. If in doubt,
interrupt installation and contact the Nice Service Centre for clarifications.
• IMPORTANT! - Important instructions: keep this manual in a safe place
to enable future product maintenance and disposal procedures.
• IMPORTANT! - Under the latest European legislation, automatic door
and gate installations must be compliant with the standards specified
in Directive 2006/42/EC (formerly 98/37/EC) (the Machinery Directive)
and the standards EN 12445, EN 12453, EN 12635 and EN 13241-1 in
particular, which enable conformity of the automated functionality to
be de clared. In the light of the above, all work involving installation,
connection, testing and maintenance of the product must be carried
out exclusively by qualified and competent technicians!

Installation warnings

• Before commencing installation, check that the product is suitable for the
intended kind of use (see paragraph 2.2 "Limits of use" and "Product technical
specifications"). If not suitable, do NOT proceed with installation.
• The contents of this manual refer to a standard system as described in fig. 2a.
• All installation and maintenance work must be carried out with the au to-
mation system disconnected from the electricity supply. If the power
discon nection device cannot be seen from where the automation system is
po sitioned, then before starting work a notice must be attached to the discon-
nection device bearing the words "CAUTION! MAINTENANCE IN PRO GRESS".
• On the power line to the system, install a device for disconnection from the
power mains with a gap between contacts that assures complete disconnec-
tion in the conditions of overvoltage category III.
• Connect the control unit to an electric power line equipped with an earthing system.
• During installation, handle the product with care, avoiding the risk of crushing,
impact, dropping or contact with any type of liquid. Never place the product
near sources of heat or expose to naked flames. This may damage prod-
uct components and cause malfunctions, fire or hazardous situations. If this
oc curs, suspend installation immediately and contact the Nice Service Centre.
• Never make modifications to any part of the product. Operations other than as
specified can only cause malfunctions. The manufacturer declines all liability
for damage caused by makeshift modifications to the product.
• The product's packaging materials must be disposed of in full compliance
with local regulations.
Safety warnings
• The product should not be used by children or people with impaired physical,
sensorial or mental capacities or who have not received adequate training in
the safe use of the product.
• In the vicinity of the automation children must be supervised to ensure that
they do not play with it.
• Do not allow children to play with the fixed control devices. Keep remote
control devices out of the reach of children.
PRODUCT DESCRIPTION AND
1
INTENDED USE
MC824HR is an electronic control unit for the automation of gates with swing-
ing leaves fitted with Toona series motors model 5624I (see paragraph "2.2
Product application limits). IMPORTANT! - Any other use than as speci-
fied herein or in environmental conditions other than as stated in this
manual is to be considered improper and is strictly prohibited!
The control unit is ready for connection to devices belonging to the Opera sys-
tem, the Bluebus system and the Solemyo solar energy supply system.
If powered from the mains, it can house a buffer battery (model PS324, option-
al accessory), which ensures that the automation can perform a number of
manoeuvres for several hours in the event of a power failure.
Other available accessories include the dedicated receivers with "SM" fitting
(SMXI, OXI, etc.).
2

INSTALLATION

2.1 - Preliminary checks for installation

Before proceeding with installation, check the condition of the product compo-
nents, suitability of the selected model and conditions of the intended installa-
tion environment:
• Ensure that all material used is in perfect condition and suitable for use.
• Ensure that all conditions of use remain within the limits of product applica-
tion (paragraph 2.2) and within the limit values stated in the "Product techni-
cal specifications".
• Ensure that the selected installation environment is compatible with the over-
all dimensions of the product (fig. 1).
• Ensure that the selected surfaces for product installation are solid and guar-
antee a stable fixture.
• Make sure that the fixing zone is not subject to flooding. If necessary, mount
the product raised from the ground.