403-1 System, Distributing Pro-Joining-Sorting Inline – Operating instructions
16.4 Terminal assignment table for Sorting Inline station
Digital (XG1)
Function
SysLink
I0
13
I1
14
I2
15
I3
16
I4
17
I5
18
I6
19
I7
20
Q0
1
Q1
2
Q2
3
Q3
4
Q4
5
Q5
6
Q6
7
Q7
8
24 V A
9+10
24 V B
21+22
GND A
11
GND A
12
GND B
23+24
16.5 Networking the system
In the case of the MPS System 403-1 with Siemens controllers, the controllers, the PROFINET bus node and
the RFID gateways are connected to each other via three 8-port switches. These switches are found at the
rear in the respective stations in the carriage.
50
Color
Gray-pink
Red-blue
White-green
Brown-green
White-yellow
Brown-yellow
White-gray
Gray-brown
White
Brown
Green
Yellow
Gray
Pink
Blue
Red
Black
White-pink
Brown-pink
Purple
White-blue
Cable jumpers are connected from emergency off to bit 1.5 on all preferred PLC
versions.
Designation
Workpiece at start of conveyor
Deflector 1 advanced
Deflector 2 advanced
Slide is full/workpiece not at end of conveyor
Workpiece detected
Workpiece not black
Workpiece metallic
Conveyor belt forward
Conveyor belt reverse
Advance deflector 1
Advance deflector 2
24 V supply for outputs
24 V supply for inputs
0 V supply for outputs
0 V supply for outputs
0 V supply for inputs
© Festo Didactic 8129446