Télécharger Imprimer la page

Festo Didactic MPS 403-1 System Notice D'utilisation page 44

Publicité

Les langues disponibles

Les langues disponibles

403-1 System, Distributing Pro-Joining-Sorting Inline – Operating instructions
16 Technical data
16.1 General data
Parameter
Operating pressure
Operating voltage
Digital inputs/outputs
Inputs:
Outputs:
Analog inputs/outputs
Inputs:
Outputs:
Digital input/outputs via IO-Link gateway (Distributing Pro station)
Inputs:
Digital input/outputs via IO-Link DA interface (Joining station)
Inputs:
Outputs:
Digital inputs/outputs via RFID gateway (Sorting Inline station)
Inputs:
Outputs:
Electrical connection
Pneumatic connection
Compressed air consumption at 600 kPa (continuous cycle)
Dimensions
Subject to change
44
28 (15+6+7)
19 (9+6+4)
1
1
3
4
4
1
1
Value
600 kPa (6 bar)
4x 230 V "IEC power cable"
Each station 24 V DC, 4 A, ≤ 100 W output power,
SELV/PELV limited power supply (LPS)
Max. 24 V DC
Max. 2 A per output
Max. 4 A total
0...10 V DC
or ± 10 V DC
24 V DC
Max. 0.5 A per output
Max. 2 A total
24 V DC
Max. 0.5 A per output
Max. 2 A total
24 V DC
Max. 0.5 A per output
Max. 2 A total
Protective contact plug
RJ-45 network connection
Plastic tubing with 6 mm outside diameter
10 l/min
1400 mm x 700 mm x 1705 mm
© Festo Didactic 8129446

Publicité

loading

Ce manuel est également adapté pour:

8130882