The negative (-) connection must be connected to the negative terminal of the same battery that the trolling motor negative lead
connects to. In the diagrams below this battery is labeled "Low Side" Battery. Connecting to any other trolling motor battery will input
positive voltage into the "ground" of that accessory, which can cause excess corrosion. Any damage caused by incorrect connections
between battery systems will not be covered under warranty.
Automatic Jump Start Systems and Selector Switches
Automatic jump start systems and selector switches tie the negatives of the connected batteries together. Connecting these systems
to the "High Side" Battery or "Middle" Battery in the diagrams below and will cause significant damage to your trolling motor and
electronics. The only trolling motor battery that is safe to connect to one of these systems is the "Low Side" Battery.
NOTICE:
The internal bonding wire is equipped with a 3 amp fuse. Improper connections described above carrying in excess of
3 amps will blow this fuse and no further damage will be exhibited. If this occurs, RF interference from the trolling motor affecting
sonar units and other electronics will be more significant. If the fuse is blown the wiring error should be found and addressed prior
to replacing the fuse. The replacement fuse should be 3 amps or less. An intact fuse does not imply correct rigging; significant
damage can be done by incorrect wiring without approaching 3 amps of current.

CONNECTING THE BATTERIES

12-Volt Systems
1.
Make sure that the motor is switched off (speed selector on "OFF" or "0").
2.
Connect positive ( + ) red lead to positive ( + ) battery terminal.
3.
Connect negative ( – ) black lead to negative ( – ) battery terminal.
For safety reasons do not switch the motor on until the propeller is in the water. If installing a leadwire plug, observe proper polarity
and follow instructions in your boat owner's manual.
For safety reasons, disconnect the motor from the battery or batteries when the motor is not in use or while the battery/batteries are
being charged.
Improper wiring of 24/36 volt systems could cause battery explosion.
Keep leadwire wing nut connections tight and solid to battery terminals.
Locate battery in a ventilated compartment.