17-04-2015
D812032_01
To edit the various parameters and
logic settings, the cells must be
unlocked by pressing the "Edit"
button; and for the changes to then be
saved, you must press the "Confirm"
button or save the control unit.
Pressing "Undo" cancels the changes
and the parameter and logic settings
are reset to their previous settings
prior to the changes.
When you enter "Diagnostics" – which
is only enabled when a control unit is
Connected – a mimic display graphical
interface opens via which you can
send a series of commands – START,
STOP, OPEN, CLOSE, PEDESTRIAN – to
connected control units and, if
nd
configured, activate the 2
RADIO
CHANNEL.
As commands are being executed, the
operation of the motors is monitored
with graphs showing the threshold
current, the actual current demand and the position.
The two INPUTS and OUTPUTS columns show the state of each.