Operation; Ch1/Ch2 Independent Mode - Metrix AX 1360P Notice De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

1. CH1/CH2
Independent Mode
Background /
Connection
Output rating
Panel operation
IV - 40
CH1 and CH2 outputs work independent of each other and are separately
controlled.
0 ~ 30 V / 0 ~ 3 A for each channel
1. Make sure the PARA INDEP and SERIES
INDEP keys are turned off (the key LEDs are off)
2. Connect the load to the front panel terminals,
CH1 +/-, CH2 +/-.
3. Set the CH1 output voltage and current. Press
the CH1 switch (LED turns on) and use the
Voltage and Current knob. By default, the
Voltage and Current knob work in
mode. To activate the fine mode, press the
knob and turn on the FINE LED.
Coarse: 1V or 0.1A @ rotation click.
Fine: the smallest digit @ rotation click.
4. Repeat the above settings for CH2 channel.
5. To turn on the output, press the output key.
The key LED turns on and the CH1 /CH2
indicator shows the output mode, CV or CC.
Operation
the coarse
DC Power Supply

Publicité

Chapitres

Table des Matières
loading