Operation
Operation (contd.)
2. CH3 Independent
Mode
Background /
Connection
Output rating
No tracking
Serial/Parallel
mode
Panel operation
CC to CV
DC Power Supply
The CH3 rating is 2.5 V / 3.3 V / 5 V, maximum 3 A. It works independently
from CH1 and CH2, regardless of their modes.
Fixed 2.5 V / 3.3 V / 5 V, 3 A
CH3 does not have tracking serial/parallel mode. Also, CH3 output is not
affected by CH1 and 2 modes.
1. Connect the load to the front panel CH3
+/- terminal.
2. Select the output voltage from 2.5 V, 3.3 V
and 5 V, using the CH3 voltage selector
switch.
3. To turn on the output, press the output
key. The key LED turns on.
When the output Current level exceeds 3A,
the overload indicator turns red and CH3
operation mode switches from Constant
Voltage to Constant Current.
"Overload" in this case does not mean
an abnormal operation.
IV - 41