located inside the woodbox in correspondence of
the combustion chamber. For the connection, we
A
Picture 16 - Possible connections of the air intake of the cooker. A= External air intake not connected,
B= External air intake on the floor, C=External air intake on the wall.
To make the connection easier we suggest to make
the external air intake on the floor in correspond
ence with the internal part of the plinth, or on the
wall through the rear part of the cooker according
WARNING! Aspiring hoods or extracting air fans in the room may generate problems to
the device if there is not a suited air intake or in case of air intake sub-dimensioned.
A
External air entry
B
C
Picture 17 - Rear sight of the plinth of the wood
fired cooker and specifies for the con-
nection with the air intake.
WARNING! For the correct working of the wood fired cooker verify that the passage of
comburent air is not obstructed or, in case of connection with external air intake, that the
air aspiration grill is not obstructed.
suggest to use a flexible pipe.
B
to specifies depending on the model (see picture
17 and table 4). Are also possible other solutions
for the connection but they must be decided to
gether with Rizzoli.
Models
RE 40 RVE 40
RE 45 RVE 45
H
RE 50 RVE 50
RE 60 RVE 60
RE 80 RVE 80
RE 90 RVE 90
B
RE 100 RVE 100
RI 60 RVI 60
RI 70 RVI 70
RI 80 RVI 80
RI 90 RVI 90
RI 100 RVI 100
Table 4 - Dimensions for the connection of the external
air intake
Dimensions in mm
83
C
A
B
C
H
95
76
243
272
95
76
293
272
95
76
343
272
95
76
443
272
95
76
643
272
95
76
743
272
95
76
843
272
95
76
443
272
95
76
543
272
95
76
643
272
95
76
743
272
95
76
843
272
ø
95
95
95
95
95
95
95
95
95
95
95
95