i) Resetting programmed user data
If you lose information about programmed data (e.g. you forget the information, or you are the
new owner of the building), you can reset all user data. Follow the steps below to reset the
data. Press the keys in the order shown in the left-hand diagram to select a function. Follow the
instructions on the right-hand side.
3
2
8
9
*
8
9
0
1
#
8
9
0
0
#
*
j) Configuring the relay function
40 + [open duration - 1 to 999 seconds] + # = time switch mode
The relay can be configured to function in different ways. In time switch mode, the relay is
activated for a preset duration when the correct user code is entered. After the preset duration,
the relay automatically switches off and the code lock switches to standby mode. The activation
time can be set from 1 to 999 seconds.
3
2
8
9
*
Enter the master code (in this example, the master code is "3289")
to enable programming mode, and then press the * key. The code lock
will beep twice and the yellow LED will stay constant to indicate that
programming mode is enabled.
Enter the delete code "8901" or "8900", and then press the # key to confirm
your entry. All saved data (user-specific codes and other programmed
data) will be deleted, apart from the master code and function codes. The
code lock will beep twice and the yellow LED will flash rapidly to indicate
that the data has been deleted, after which the code lock will switch to
multi-user mode (if you entered "8901") or single-user mode (if you entered
"8900"). The code lock is always set to manual entry mode when you delete
user data.
Press the * key to exit programming mode. The yellow LED will start to
flash again.
After deleting the data, you can enter new user data (e.g. codes) or exit
programming mode. After you have finished programming new data, press
the * key to exit programming mode.
Enter the master code (in this example, the master code is "3289")
to enable programming mode, and then press the * key. The code lock
will beep twice and the yellow LED will stay constant to indicate that
programming mode is enabled.
63