You can also temporarily block access (including for valid user codes) using the superuser code.
You can delete and add user codes at any time, making this mode ideal for use in an office
where many people require access.
After entering a 4–8 digit code, you must press the # key (hash key) to confirm your entry (when
"Auto entry" mode is disabled, this is the default setting).
The relay is activated when you enter the correct code.
Important! The master code and user codes can have different numbers of digits (e.g. you can
configure an 8-digit master code and a 5-digit user code).
However, when "Auto entry" mode is enabled (see section I "Auto entry mode (automatic code
recognition)"), the master code and user codes must have the same number of digits (4–8
digits). In this case, you do not need to confirm your entry by pressing the # key (hash key).
To switch to multi-user mode, press the keys in the order shown in the left-hand diagram. Follow
the instructions on the right-hand side.
0
0
0
0
*
8
9
0
1
#
d) Configuring a new master code
The master code is saved to memory slot 0. In multi-user mode, the master code can be 4–8
digits long. In single user mode, the master code must be four digits long. If auto-entry mode is
enabled, user codes must have the same number of digits as the master code.
Important – if you have already programmed another master code, use the new
master code.
0 + [New master code] + #
Press the keys in the order shown in the left-hand diagram. Follow the instructions on the right-
hand side.
58
Enter the master code to enable programming mode (in this example, the
master code is the factory default, "0000"). Press the * key to confirm your
entry. The code lock will beep twice and the yellow LED will stay constant
to indicate that programming mode is enabled.
Enter the mode switch code ("8901").
Press the # key to confirm your entry. The code lock will beep and the LED
will flash rapidly, after which you will hear two beeps, indicating that the
code lock has switched to multi-user mode.
If the entry was incorrect or unsuccessful, the code lock will beep and the
yellow LED will flash five times.