Technical data
Model
Voltage
Power consumption
Max. pressure
Operating pressure
Water consumption
Max. pressure water
intake
Length hp hose
Water temperature
Automatic start-stop
Protection class
Protection level
Noise level
Dimensions
Weight
Technical changes reserved
Important safety regulations
1. Check your machine for visible damage before every use (incl.
cable, plug, hose and nozzle). Do not use a machine that is
damaged or did not work perfectly on the previous occasion, but
take it to your supplier for repairs/replacement.
2. The Voltage and frequency stated on the machine must correspond
with those of the socket to be used. The electrical installations must
be approved (IEC 60364-1) and secured with an earth leakage
switch (max. 30 mAmp.). Never alter the plug or socket in order to
make them fit! Faults in the electrical connection may cause electric
shocks!
3. If an extension cable is unavoidable, use a cable of sufficient
thickness: 1 mm² for cables to 12.5 metres, 1.5 mm² for cables to
20 metres and 2.5 mm² for cables to 30 metres in length. Unroll
the cable completely during use in order to prevent overheating.
The female plug/socket must be watertight and the connection
must be kept dry and may not lie on the ground. Defective
extension cables are dangerous!
4. Take the greatest care when the machine is used near children,
handicapped people or senior citizens. Never leave them with a
working machine unsupervised!
Force 1200
AC 220-240V, 50Hz
1200 Watts
9MPa (90 bar)
60 bar
330 l/h
0,7MPa (7 bar)
3 metres
0-40°C
+
II
IPX5
77 dB(A)
20 x 25 x 42 cm
4,1 kg
24
Force 1400
AC 220-240V, 50Hz
1400W
10MPa (100 bar)
70 bar
330 l/h
0,7MPa (7 bar)
5 metres
0-40°C
+
II
IPX5
77 dB(A)
24,5 x 26,5 x 68 cm
4,35 kg