5. On the outside of the enclosure, loop and secure the
antenna cable with a wire tie (Figure 2) to help prevent
water from entering the unit.
Figure 2
6. Route the antenna cable toward the intended mounting
location of the cellular unit.
Disconnect Generator Wire Harness
Verify power is disconnected to the unit before proceeding.
1. Remove the screws and the control box front to access
the control panel. The generator will have either of two
panels (Figure 3A or 3B).
AUTO
Figure 3A
Figure 3B
MENU
ESC
OFF
MANUAL
Figure 4A
Figure 4B
2. Remove the screws to access the control board on the
back of the panel. The generator will have either of two
control boards (Figure 4A or 4B).
3. Disconnect the generator wire harness (8-wire
connector) from the control board connector J6.
C
B
Figure 5
Identify Interface Board Connections
Locate the supplied interface board in the kit. Before
proceeding, review and understand the interface board
connector assignments below (Figure 5).
A - Generator harness connector from control board
B - Fault relay wire connector
C - 240V splitter harness connector
D - Pass-through harness connector
E - Cellular unit harness connector
J6
J6
D
E
A