Are the required protection measures against electric shock
11.
in place
?
12. Are the signals for switching monitoring cases for inputs A, B,
C, D of the LSI two-channel (for more details see section 8.2,
LSI Technical Description)
13. Is the re-set / re-start switch for the ESPE installed and fitted
to the correct standard
Are the OSSDs of the ESPE connected in accordance with
14.
the machine circuit diagram
15. Have the protective functions been inspected in accordance
with the inspection instructions of this document
16. Are the switching elements controlled by the ESPE, e. g.
contactors, valves monitored
17. Is the ESPE effective during the entire hazardous state
18. Is the Daily Check Requirement sign positioned in a place
visible to the operator
This checklist does not replace the initial commissioning or
regular inspections by qualified personnel
8 008 308/M848/06-05-02 Operating Instructions · LSI
© SICK AG · Industrial Safety Systems · Germany · All rights reserved
Yes o
Yes o
?
Yes o
?
? Yes o
Yes o
? Yes o
Yes o
Yes o
?