Are the relevant safety standards incorporated into the
1.
machine build? Will they satisfy the Regulations
2. Are the standards listed in the Declaration of Conformity
3. Is the ESPE the correct Type and interfaced to the correct
Category
?
4. Is access to the danger zone / point of danger only possible
through the ESPE
Are measures in place to prevent standing between the
5.
ESPE and the danger zone? If so, are these measures
secured against removal
6. Are all monitoring cases, which can be selected by way of the
LSI designed such, that the measures in place as set out
under item 5 remain effective
Are the mechanical means positioned to avoid reaching over,
7.
under or around? (see EN294)
Has the overall machine stopping time been checked and
8.
documented
?
Is the resultant safety distance observed between the danger
9.
point and the ESPE
10. Is the ESPE correctly fixed and secured against movement
after setting in its fixed position