Télécharger Imprimer la page

SICK LSI 101 Mode D'emploi page 141

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 81
LSI
Power supply cable to PLS:
Use a copper cable with a maximum cross-section of
2
0.5 mm
. Max. cable length: 30 m
Notes:
When dimensioning the cable cross-sections dependent on
line length and power pack tolerance, make sure the system is
not operated outside its permitted voltage ranges (see
technical data of LSI and PLS).
The spring clamp female connector strips can hold cables
(single-wire, multi-wire, fine-wire or fine-wire with ferrule) with
cross-sections from 0.08 to 2.5 mm
Example table - Power supply cables:
System
LSI with two PLS
Power pack 24 V DC ± 3 %
LSI with four PLS
Power pack 24 V DC ± 3 %
LSI with two PLS
Power pack 24 V DC ± 1 %
LSI with two PLS
Power pack
24 V DC +20 %/-25 %
8 008 308/M848/06-05-02 Operating Instructions · LSI
© SICK AG · Industrial Safety Systems · Germany · All rights reserved
2
.
Power supply cable length
Power pack – LSI
2
50 m (2.5 mm
)
2
40 m (2.5 mm
)
2
24 m (1.5 mm
)
2
40 m (2.5 mm
)
2
28 m (2.5 mm
)
2
17 m (1.5 mm
)
2
50 m (2.5 mm
)
2
30 m (1.5 mm
)
2
4 m (1.0 mm
)
GB
LSI – PLS
2
10 m (0.5 mm
)
2
20 m (0.5 mm
)
2
20 m (0.5 mm
)
2
4 m (0.5 mm
)
2
20 m (0.5 mm
)
2
20 m (0.5 mm
)
2
20 m (0.5 mm
)
2
20 m (0.5 mm
)
2
4 m (0.5 mm
)
141