Télécharger Imprimer la page

SICK LSI 101 Mode D'emploi page 159

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 81
LSI
Specifications
EDM input (external contact
monitoring)
Inputs A1, A2, B1, B2, C1, C2,
D1, D2
Inputs C, D
Switchover of monitoring
cases (use of inputs A - D)
Interface (PC)
Only for temporary configuration
and diagnostic purposes
Transmission rate
RS 232
RS 422
Cable length
RS 232
RS 422
Interface (LSI - PLS)
Use of a low-capacity twisted
pair data cable of type Li2YCY
(TP) with a min. cross-section of
2 x 2 x 0.25 mm
2
Transmission rate
RS 422
Cable length
RS 422
Cable cross-section
RS 422
8 008 308/M848/06-05-02 Operating Instructions · LSI
© SICK AG · Industrial Safety Systems · Germany · All rights reserved
Data
min.
typ.
1 input per OSSD pair
(to DC 24 V)
Static binary inputs to DC 24 V
Dynamic inputs to DC 24 V
4 static binary input pairs (x1 and
x2 antivalent) A1, A2, B1, B2, C1,
C2, D1, D2 or 2 dynamic
incremental encoder inputs (C, D)
and 2 static binary input pairs (x1
and x2 antivalent) A1, A2, B1, B2
9600, 19200, 38400 Baud
9600, 19200, 38400 Baud
500kB
0.25 mm
2
GB
max.
15 m
100 m
30 m
159

Publicité

loading