* "Resetting by Battery" function
In case of power supply break-out, the door operation can be reactivated with
battery (anti-panic cycle).
Then press the "Mode" or "Priority opening" control keys on the wired selector,
or by using a locking command: manual key
The cycle will last 20 seconds after resetting, then the display on the control
panel will go out.
IMPORTANT:
"Resetting by Battery" function
(Case of emergency Exits with TÜV specifications)
In case of power supply break-out, the door operation can be reactivated with
the battery (anti-panic cycle) by using the external key contactor.
Give first an impulse on the "reset position", then lock the door by using this key
contactor.
If you want to open the door, select the "unlock" position.
Pre-tensioned rubber cord test
(Case of emergency Exits with TÜV specifications)
At regular intervals, the door checks the pre-tensioned rubber cord : from the
closed position, the door opens slowly.
If the test has not been done properly, the door will stay in the opened position
and the control panel will indicate "ds"
If you then select an operating mode, the movement will be
that of the anti-panic cycle associated with it: opening,
manual or closing.
2