1
* "Resetting by Battery" function
In the absence of a power supply (control panel not illuminated), door operation
can be reactivated by battery (anti-panic cycle).
Then press the "Mode" or "Selection" keys on the control panel, or by using a
locking command : manual key or infrared key
You can then use the remote control, the keys on the control panel, or other
commands that are connected but have no power supply, such as pushbuttons,
etc.
The cycle will last 20 seconds after resetting, then the display on the control
panel will go out.
IMPORTANT : if you then select an operating mode, the movement will be that
of the anti-panic cycle associated with it: opening, manual or closing.
"Resetting by Battery" function
(Case of emergency Exits with TÜV specifications)
In the absence of the power supply (control panel not illuminated), door
operation can be reactivated by battery (anti-panic cycle) by using the external
key contactor.
Give first an impulse on the "reset position", then lock the door by using this key
contactor.
If you want to open the door, select the "unlock" position (reverse).
Pre-tensioned rubber cord test
(Case of emergency Exits with TÜV specifications)
At regular intervals, the door checks the pre-tensioned rubber cord : from the
closed position, the door opens slowly.
If the test has not been done properly, the door will stay in the opened position
and the control panel will indicate "ds"