to deviate by more than 1.50 m from the
perpendicular to the edge for stopfor™ fall arrest
device in horizontal use (see fig. 6.1),
• to
reassemble
GB
equipment, thus creating a slack strand,
• to use other belay systems,
components than those compatible with each fall
arrest model stopfor™ as indicated in this manual,
• to use the belay device for any purpose other than
that of the intended fall arrest model stopfor™,
including with another model of fall arrest device,
• to use a lanyard longer than 0.3 m for stopfor™,
• to use an anchor line or lanyard with defects, knots
or visible signs of deterioration.
Installation before use
Install the stopfor™ on the belay line.
The stopfor™ BF is installed on its string, it is not
removable.
Connect the stopfor™ to the fall arrest harness
the connector that is directly positioned on the
stopfor™ or with the connector positioned at the end
of the stopfor™ lanyard.
Then, the procedure to follow is as follows:
For stopfor™
B/MSP/K/KS/KSP
• Open the device by rotating the flange
mobile.
• Tilt the cam with your finger to release the passage
of the belay bracket.
• Insert the belay device between the axis of the
pinch and the cam.
• Close the movable flange as far as it will go on the
axis
of pinching.
• Insert the
M10
stopfor™
into the holes of the two fixed and
movable flanges, which allows the device to be
locked.
• The stopfor™ must be oriented on the belay device
in such a way that the arrow points upwards, with
the device locked.
In case of a fall, the stopfor™ automatically stops the
operator.
For stopfor™ SL,
• take the stopfor™ S in your hands,
• lift the jaw lever upwards,
• unlock the lock by rotating it upwards,
• unscrew the knurled knob,
• open the swivel flange,
• stopfor™ must be oriented on the belay line in a
such way that the arrow points upwards when the
10
the
belay
system
lanyards and
8. Installation
connector
supplied with the
device is locked. If the arrow is pointing downwards,
the coded pin prevents the instrument from closing.
• place the belay bracket in the flanges,
with this
• close the flanges,
• screw in the knurled knob,
• lock the lock by rotating it downwards. In case of a
fall, the stopfor™ automatically stops the fall.
1. Anchoring to the structure (Figure 1, page 2, A)
•
The belay bracket is fixed to the anchorage point
by a loop (Fig. 1, page
(Fig. 1, page 2,
minimum strength of 12 kN.
The anchor point of the belay system must
never be positioned below the user.
with
2. Mounting configurations
The stopfor™ must only be mounted on a vertically
suspended anchor line or with a maximum angle of
30° to the
vertical
• the stopfor™ can be positioned on the belay
bracket in front of the user for vertical movement
with a maximum angle of 30° or a maximum
movement of 3 m with respect to the vertical.
• the stopfor™ can be positioned on the belay
bracket behind the user for vertical movement with
a maximum angle of 30° or a maximum movement
of 3 m with respect to the vertical.
• the stopfor™ can be positioned on the belay
bracket in front of the user for a horizontal
movement with a maximum angle of 30° or a
maximum movement of 1.5 m with respect to the
vertical.
The anchor line must not be slack between
the anchor point and stopfor™. It must be
ensured that its length is sufficient.
anchor point of the belay system must never
2,
C/K) and a connector
J). The anchor point must have a
DANGER
or on a horizontal plane (see fig. 6).
DANGER
be positioned below the user.
The