3.5
Control switch
Symbol
Meaning
Switching on
Switching off
Operating switch: Manual filter cleaning
3.6
Using the filter cleaning system
The vacuum cleaner features manual filter cleaning. To obtain maximum suction power, use the filter cleaning
system to bump-clean the filter at regular intervals.
1. Close off the end of the hose.
2. Wait until maximum vacuum has built up.
3. Press the
operating button 4-5 times in succes-
sion.
3.7
Instructions for use
Accessories and how they are used
Accessories
Filter, polyester
Filter, PTFE
Filter, HEPA
4
Technical data
4.1
Product properties
If the appliance is powered by a generator or transformer, the generator or transformer's power output
must be at least twice the rated input power shown on the rating plate of the appliance. The operating
voltage of the transformer or generator must always be within +5 % and -15 % of the rated voltage of
the product.
Weight
Dimensions (L x W x H)
Max. volume flow rate (turbine data)
6
English
Order number
Type of use
2182582
Universal use, wet and dry
2202240
Heavy use, wet and dry
2177708
Wet and dry
VC 300-20-W
63.1 lb
(28.6 kg)
27.6 in × 19.9 in × 39.0 in
(700 mm × 505 mm × 990 mm)
300 CFM (2×71 ℓ/s)