Installation; Installation Instructions; Required Tools; Drain Valve For Ø280, 330, 400 Container - aqua technix AQ 280 Traduction Du Instruction D'utilisation Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation

4
Installation
4.1

Installation instructions

4.1.1

Required tools

Pipe wrench
Screwdriver
Rubber mallet
Hand saw
Cutting knife
4.1.2
Drain valve for Ø280, 330, 400 container
The drain valve (item 21-27) is mounted on the filter container (2).
To do so slide the o-ring (21) over the buttress thread and the
o-ring (24) over the thread G ¾" on the valve (22). Then the valve
(22) is screwed on to the filter container (2) with the o-rings. Press
the flat seal (25) into the socket (26) and place this combination in
the screw nozzle G ¾" (27). This complete unit must then be
screwed onto the inch thread of the drain valve (22).
25
26
27
Drain valve for Ø500 container
The drain valve (item 21-25) is mounted on the filter container (2).
To do so slide the flat seal (22) onto the drain valve (21). The
drain valve (21) must be pushed through the filter container (2)
from inside. Push the second flat seal (22) over the thread on the
drain valve (21) from outside. Screw the nut (23) on the thread of
the drain valve (21) and tighten it. Lay the flat seal (24) in the seal
14 EN
21
22
24
2
WG23.400.003-P
06|2019

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aq 300Aq 400Aq 500