Aprimatic 4M Montage page 9

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4M
sensors and correct movement. You are advised to install the
blind with it half open to check the confi rmation movements
during the test. Make sure you disable the Line Sensor Test
after checking the sensors' operation.
Anemometer test: turn the blades manually; the control unit
will raise the blind for 5 seconds.
Sun sensor test: expose the Sun Sensor to the sun or light
source; the control unit switches on the SUN LED and lowers the
blind for 5 seconds. Cover the Sun Sensor and the control unit
will switch off the SUN LED and raise the blind for 5 seconds.
Rain sensor test: dampen the sensitive part of the Rain Sensor;
the control unit will switch on the RAIN LED and raise the blind
for 5 seconds. At the end of the test, make sure you dry off the
sensitive part of the rain sensor before using the control unit in
normal operating mode.
Programming: The control unit comes with a Line Sensor Test
disabled. If you wish to enable the Line Sensor Test, proceed
as follows: enable the extended menu (the SUN and RAIN
LEDs will fl ash to confi rm this); use the SEL key to navigate to
the SENSOR CODE LED and then press the SET key; at the
same time, the SENSOR CODE LED switches on permanently
and programming is complete. Repeat this procedure to restore
the initial confi guration.
F) T. MOT. (Automatic Movement Lock)
The control unit allows you to lock automatic movement (Upward
or downward movement of the blind controlled by the Sun
Sensor command or function of the Automatic Sensors); in this
way, the control unit temporarily blocks automatic motion when
a stop command is given during movement until the next raising
or lowering command. The control unit comes with the Automatic
Movement Lock disabled; to enable this function, proceed as
follows: enable the extended menu (the SUN and RAIN LEDs
fl ash to confi rm this), press the SEL key until the T.MOT LED
fl ashes, then press the SET key; at the same time the T.MOT
LED switches on permanently and programming is complete.
Repeat this procedure to restore the previous confi guration.
G) WIND SPEED (Safety Upward Movement)
The control unit comes with the Safety Upward Movement
disabled; to enable this function, so that after 12 hours of
the Wind Sensor being inactive the control unit automatically
executes the safety upward movement, proceed as follows:
enable the extended menu (the SUN and RAIN LED will fl ash
to confi rm this), press the SEL key until the WIND SPEED
LED fl ashes, then press the SET key; at the same time the
WIND SPEED LED switches on permanently and programming
is complete. Repeat this procedure to restore the previous
confi guration.
H) SUN SENSOR (Sun sensor control inversion)
The control unit comes with the Sun control = Downward
movement control association, so the sensor controls the
downward movement of the blind when it detects the sun. If
you wish the sun sensor to control the upward movement of
the blind when it detects the sun, proceed as follows: enable
the extended menu (the SUN and RAIN LEDs fl ash to confi rm
this), press the SEL key until the SUN SENSOR LED fl ashes,
then press the SET key; at the same time the SUN SENSOR
LED switches on permanently and programming is complete.
Repeat this procedure to restore the previous confi guration.
I) RAIN SENSOR (Rain sensor control inversion)
The control unit comes with the Rain control = Upward
movement control association, so the sensor controls the
upward movement of the shutter when it detects the sun. If you
wish the rain sensor to control the downward movement of the
shutter when it detects the rain, proceed as follows: enable the
extended menu (the SUN and RAIN LEDs fl ash to confi rm this),
press the SEL key until the RAIN SENSOR LED fl ashes, then
press the SET key; at the same time the RAIN SENSOR LED
9
switches on permanently and programming is complete.
Repeat this procedure to restore the previous confi guration.
RESET
If you need to restore the control unit's default settings, press the
SEL and SET keys together to switch on all the indicator LEDs
at the same time and then switch them off again immediately.
5.
IMPORTANT NOTES FOR THE INSTALLER
The control unit was designed to allow the installer to automate
the shutter in accordance with legislation in force. The installer
must comply with safety obligations and minimum requirements.
Installation must be carried out according to EN 60335-2-97
"Specifi cation for safety of household and similar electrical
appliances" part 2 "Particular requirements for drives for rolling
shutters, awnings, blinds and similar equipment"- The control
unit must be connected permanently to the power supply
and it is not equipped with a 230 V a/c electric line sectioning
device. The installer is responsible for installing a sectioning
device in the system. He should install an omnipolar switch
with category III overvoltage. It must be positioned so that it
is protected against accidental closure.- Connections (power
supply, motor output) should be made using fl exible cables with
harmonized polychloroprene insulation sheathing (HO5RN-F)
and the conductors' minimum cross-section is 0.75 mm².- The
connecting cables should be attached by fi tting the cable clamps
provided in the product.
6.
IMPORTANT NOTE FOR THE USER
- The device must not be used by children or people with any
psychological or physical disability, unless they are supervised
or taught how to use it with care.
- Do not let children play with the device.
ATTENTION: keep this instruction manual and comply with the
important safety instructions inside. Failure to comply with
these instructions could cause damage and serious accidents.
- Inspect the system frequently to check for any signs of
damage. Do not use the device if it is in need of repair.
ATTENTION
All operations that require opening the casing (cable connection,
programming, etc.) must be executed during installation by a
qualifi ed technician. Please contact the Technical Assistance
Service should any other work that requires opening the casing
arise (reprogramming, repair or installation changes).
EN

Publicité

Table des Matières
loading

Table des Matières