4M
Setting the wind safety threshold between 5 and 40 Km/h
The control unit comes with a wind safety threshold already set
at 25 km/h (WIND SPEED LED OFF).
The wind safety threshold is programmed as follows: use the
SEL key to navigate to the WIND SPEED LED, then press the
SET key to start programming; the WIND SPEED LED will then
begin to double-fl ash (each double fl ash of the WIND SPEED
LED corresponds to an increment of 5 km/h). Press the SET key
once the required threshold has been reached. The selected
threshold is stored and the WIND SPEED LED stays ON (e.g.
the WIND SPEED LED fl ashes 5 times = 25 km/h).
The operation may be repeated if a mistake is made during
programming.
8)
SUN SENSOR (Sun Sensor ON/OFF)
Enabling the sun sensor
The control unit comes with a Sun Sensor disabled (SUN
SENSOR LED OFF).
The Sun Sensor can be enabled as follows: use the SEL key to
navigate to the SUN SENSOR LED then press the SET key for
a second. The SUN SENSOR LED stays ON at the same time.
The Sun Sensor is now enabled. Simply repeat this procedure
to disable the Sun Sensor.
9)
RAIN SENSOR (Rain sensor ON/OFF)
Disabling the rain sensor
The control unit comes with a Rain Sensor enabled (RAIN
SENSOR LED ON).
The Rain Sensor can be disabled as follows: use the SEL key
to navigate to the RAIN SENSOR LED, then press and hold the
SET key for a second. The RAIN SENSOR LED switches off
and the Rain Sensor is disabled. Simply repeat this procedure
to enable the Rain Sensor.
EXTENDED MENU
The manufacturer provides the control unit with only the option
of selecting the functions of the main menu.
If you wish to enable the functions of the extended menu,
proceed as follows: press and hold the SET key for 5 seconds;
the SUN and RAIN LEDs will fl ash alternately; you then have
30 seconds within which to select the functions of the extended
menu using the SEL and SET keys; after another 30 seconds
the control unit returns to the main menu.
LED reference Led OFF
A) CODE M1
Step by step
B) CODE M2
Step by step
C) CODE M3
Simultaneous start-up 5 s. sequential start-up
D) CODE M4
Start-up delay time =
OFF
E) CODE SENS. Line Sensor test = OFF Line Sensor test = ON
F) T. MOT.
Aut shutdown = OFF Aut shutdown = ON
G) WIND SPEED Safety up movmt=OFF Safety up movmt = ON
H) SUN SENSOR RAIN inversion = OFF RAIN inversion = ON
I) RAIN SENSOR SUN inversion = OFF SUN inversion = ON
L) SUN
M) RAIN
Led ON
Manual/P-P S.Aut.
Venetian blind/P-P S.
Aut.
Start-up delay time =
Pgm
ON/OFF intermittent
ON/OFF intermittent
8
A – B) CODE M1 – M2
(4 different selectable operating logics)
Step by step
Step by step operation is possible using the pushbutton control.
The fi rst impulsive control raises the blind for the motor time.
The second impulsive control lowers the blind. If an impulsive
command is sent before the motor stops running, the control
unit stops the blind; another impulsive command re-activates
the blind in the opposite direction.
Manual
Manual operation is possible using the pushbutton control.
The control needs to be constantly enabled to move the blind.
Releasing the key will always stop operation.
Venetian blind operation
The Venetian blind mode involves manual operation for the fi rst
2 seconds using pushbutton control; this allows you to turn the
slats of the Venetian blind ever so slightly to let more or less
light into the room as required. If the commands are more than
2 seconds, the blind is raised or lowered depending on the key
pressed, until the motor stops running.
Step by step + Automatic sensors
The control unit enables step by step operation as above, as
well as automatic management of the Wind and Rain sensors.
Ten minutes after the wind or rain that activated one of the two
sensors, the control unit lowers the blind.
Selection mode
The control unit allows you to select 4 different operating
logics: step by step, manual, Venetian blind and step by step
+ automatic sensors.
The control unit is provided with step by step operation already
enabled(M1 CODE LED AND M2 CODE LED disabled). If you
wish to enable the other operating mode, proceed as follows:
enable the extended menu(the SUN and RAIN LEDs will fl ash
to confi rm this); use the SEL key to navigate to the M1 CODE
LED, then press the SET key to enable the Manual function;
use the SEL key to navigate to the M2 CODE LED, then press
the SET key to enable the Venetian blind function, or use the
SEL key to navigate to the M1 CODE LED and M2 CODE LED,
then press the SET key to enable the Step by step + Automatic
Sensors function.
C) CODE M3
(Simultaneous or sequential start-up)
The control unit is provided with simultaneous start-up of the
4 motors already enabled. If you wish to have a 5-second
interval in between the start-up of each motor, proceed as
follows: enable the extended menu(the SUN and RAIN LEDs
fl ash to confi rm this), use the SEL key to navigate to the CODE
M3 LED and then press the SET key; at the same time the
CODE M3 LED switches on permanently and programming
is ended. Simply repeat this procedure to restore the previous
confi guration.
D) CODE M4
(Programming the start-up delay time)
The control unit allows you to program a start-up delay time
for the 4 motors; this prevents other interconnected sets of
4 motors from starting up simultaneously. The control unit is
provided without start-up delay time for the 4 motors; to program
a start-up delay time of between 1 and 120 seconds, proceed as
follows: enable the extended menu(the SUN and RAIN LEDs will
fl ash to confi rm this), use the SEL key to navigate to the CODE
M4 LED, then press the SET key for the required delay time; as
soon as you release the key, the M4 CODE LED switches on
permanently and programming is complete. Simply repeat this
procedure to make any changes to the confi guration.
E) SENS. CODE
(Line Sensor Test)
The control unit allows you to check operation of the connected
EN