Technical Data

Description
Rated voltage
Switch contact
Frequency
Standby power
Sensor angle
Sensor range
(20°C and 2.5 m in height)
Recommended installation height
Angle of rotation sensor head
Operating mode
Switch-on duration (continuous)
Twilight threshold continuous)
3-wire connection technology
110°
Article No.: 823712018
230 V~
Open contact (μ opening
width)
50 Hz
< 1 W
110°
10 m (frontal)
0.5 m (backwards)
2.5 m
horizontal: -15°
vertical: ± 25°
Auto
Approx. 6 sec - approx.
10 min, test, pulse
(1 s "On", 9 s "Off")
5 Lux – ∞
(L, N, switching wire to
consumer)
180°
Article No.: 823812011
230 V~
Open contact (μ opening
width)
50 Hz
< 1 W
180°
10 m (frontal)
0.5 m (backwards)
2.5 m
horizontal: -15°
vertical: ± 25°
Auto
Approx. 6 sec - approx.
10 min, test, pulse
(1 s "On", 9 s "Off")
5 Lux – ∞
(L, N, switching wire to
consumer)
270°
Article No.: 822012016
230 V~
Open contact (μ opening
width)
50 Hz
< 1 W
270°
10 m (frontal)
7 m (backwards)
2.5 m
horizontal: -15°
vertical: ± 25°
Auto
Approx. 6 sec - approx.
10 min, test, pulse
(1 s "On", 9 s "Off")
5 Lux – ∞
(L, N, switching wire to
consumer)