Technical Data

Description
Rated voltage
Switch current to connect heating, ventilation,
air-conditioning (HVAC) devices
Switch contact
Frequency
Standby power
Detection angle
Detection range (20 °C and 2.5 m high)
Recommended installation height
Angle of rotation sensor head
Operating mode
ON time (continuous)
Twilight threshold (continuous) (lux)
Learn mode
3-wire connection technology
Switching capacity (resistive load)
Bulbs
Low-volt halogen lamps (AC)
High-volt halogen lamps (LV)
88
220–240 V~
max. 10 A; cos φ = 1; ≤ 250 VAC
max. 5 A; ≤ 30 VDC
max. 3 A; cos φ = 0.4; ≤ 250 VAC
closer (μ opening width)
50/60 Hz
< 0,9 W
240°
16 m (frontal), 8 m (backwards)
2.5 m
horizontal: ± 90°
Auto / Manual Override
approx. 5 sec. - approximately 30 min., test, pulse
5 Lux – ∞
, 5 Lux – 500 Lux, holiday
(L, N, switch wire to the consumer)
max. 2,300 W
max. 2,300 W
max. 1,200 W
max. 1,000 W