Troubleshooting
Problem
Cause
Light not
Defective bulb
switching
Fuse switched off
Response brightness set to dark
Supply interrupted
Coverage area not set correctly
Lens dirty
Light on
Constant movement in the coverage area
constantly
(animals, trees, etc.)
Switch-on duration is too long
Selbstständiges,
Switching on after power failure
unerwünschtes
Sunlight on the lens
Schalten
Trees, shrubs, etc. triggering switching in
the wind
Detection of road traffic
Switching inductive consumers (covers,
relays, etc.)
Solutuion
Replace bulb
Switch on
Turn the setting screw in the direction of light
Check supply, repair if necessary
Correct area - test walk in coverage area
Clean lens (damp cloth)
Do not use solvents
Remove heat source
Re-adjust motion switch if necessary
Reduce switch-on duration using the setting screw for
"Time"
Normal case - warm-up phase approx. 90 sec.
Change brightness setting
Chang coverage area or partially cover lens with the
enclosed plastic covers
Reduce sensor range (e.g. using settings on the setting
screw for „Meter") or partially cover lens with the enclosed
plastic covers
Switch the interference filter parallel to the consumer