INSTRUCTIONS FOR PREFABRICATED POOLS, THIN WALLS OR POLYSTYRENE BLOCKS
7
4
5
Index
Nbr
Component designation
1
1
Fastener frame
2
1
Stainless steel fastener bracket
3
1
Fastener support plate
4
2
UPAT bushing M8x50
5
1
Fastener frame gasket
6
4
Countersunk flat head socket screw M6-20
7
4
Countersunk flat head socket screw M8-20
8
4
Washer Z6
9
4
Nut H M6
10
1
Stainless steel slide rod
11
1
Trim
Using the fastener support (3) as a template, drill holes (Ø 10 mm - depth 8 mm).
Attach the fastener support plate under the coping using 2 UPAT bushings M8x50 (4) and 2 countersunk flat head socket screws (7).
The fastener frame (1) will be attached to the support plate (2) using 4 countersunk flat head socket screws M6x20 (6) washers Z6
(8) and hex nuts M6 (9).
B
LOCKING THE SLAT COVER CLOSED USING THE FASTENING STRAPS
Once the cover has been fully rolled out on the surface of the water, press the button "A" and slide the slide bar upwards, then lower it
down through the ring at the end of the strap. Push the slide bar down fully (you will hear a click) to ensure that it is locked.
R
:
ELEASING THE SLAT COVER
Press in the button "A" and pull the slide bar up to release the strap.
DO NOT FORGET TO RELEASE THE STRAPS BEFORE ROLLING THE COVER UP,
U
2 P
U
2 P
SE
A
ART
FASTENER
SE
A
ART
FASTENER
3
6
2
7
A
THE USE OF FASTENING STRAPS IS MANDATORY UNDER FRENCH LAW
FAILURE TO DO SO COULD LEAD TO SERIOUS DAMAGE
ATTACHED
UNDER
ATTACHED
UNDER
1
8
9
11
10
:
45/76
2009/02 - Indice de révision : D - code : 0035431
.
.
THE
COPING
THE
COPING
Cut-out in the coping