CONNECTION OF THE END OF TRAVEL SENSORS
Connect the "A", "T" and "C" terminals in the control panel to the "A", "T" and "C" terminals of the motor
junction box.
This connection must be made using a continuous length of shielded cable the metallic braid of which
should be connected to the the B terminals in the control panel and the motor junction box.
CONNECTION OF THE JUNCTION BOX TO THE MOTOR
Once all the electrical connections have been made, plug the two junction box quick fit connectors into
the motor. The connectors are "fool-proof" to avoid any confusion. Hand tighten the quick fit connector
screws.
CONNECTION OF THE CLEANING MANIFOLD BOOSTER (Option)
The booster should be connected using a 3 x 2.5
located to the left of the 220 V power supply. The earth wire of this cable should be connected to the earth
terminal.
Note: The cleaning manifold cannot be installed on pools wider than 6 m.
The cleaning manifold will operate each time the slat cover moves in or out if the control switch (to the right
of the on/off switch) is closed.
Key switch box
2
WIRING DIAGRAM
Control panel connection terminals
Motor junction box
Boîtier de
raccordement
du moteur
To motor
Vers moteur
(pre-wired)
(déjà câblé)
55/76
cable connected to terminals 2 and 6 of the contactor
cable shielding
ferrite ring
Power supply 220 V + earth
cable shielding
(Cleaning manifold option)
2009/02 - Indice de révision : D - code : 0035431