Using The Device; Cleaning And Maintenance; Troubleshooting - Dometic S16031 D Plus Instructions De Montage Et De Service

Simulateur actif
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
D+ Active Simulator
✔ If the LED is blinking red the voltage detection is turned off successfully.
➤ Select the requested switch-off delay and the setup mode automatically exited.
I
NOTE
The device factory default settings are:
• Voltage detection is active.
• Switch-off delay is 60 s.
9

Using the device

The operating status is shown by different blinking cycles of the LED (fig. 2, page 4, 1).
LED
Blinking red
Blinking green
Blinking yellow
Blinking three times red
Blinking three times green
Blinking red and green alternately
10

Cleaning and maintenance

The device is maintenance-free.
11

Troubleshooting

Fault
The device is not work-
ing at all.
No function, yellow
LED blinking.
EN
Operating status
Standby, D+ signal off
D+ signal on
Setup mode
Voltage detection off
Voltage detection on
Determining voltage range
Possible cause
Blown fuse.
Poor power supply con-
tact.
Wrong power supply
polarity.
Setup mode is active.
Solution
Replace the fuse.
Clean battery terminals and the device wir-
ing contacts.
Connect the device properly.
Set the correct switch-off delay.