ε
65-410
R,L,C
To save a light scene, you proceed as follows:
1. Set the desired light scene by means of input 1.
2. Keep input 2 pressed for 3s. The connected load first dims to the previous set light scene and
after 3s. dims to the desired light scene.
3. The light scene has been set.
The light scene can be recalled at any time by pressing input 2.
To exit the light scene and switch off the load, use input 1.
It is possible to simultaneously call up the light scenes of different light circuits by means of the
single push button control. To this end, connect terminals 2 and 3 of the dimmers that control the
relevant light circuits.
After a power failure the load is switched off (fig.8).
Multiple switch points with NO contacts (not illuminated) can be connected. Up to 30 NO contacts
(170-0000X) can be connected in parallel. The maximum distance is 100m
Mode 4: double push button control
In double push button mode, input 1 (terminals 3 - 4) and input 2 (terminals 2 - 3) together function
as a double push button dimmer (fig.4).
Memory function:
With memory
Briefly press input 1: the load is switched off.
Keep input 1 pressed: dimming down.
Keep input 2 pressed: the load is switched on at previous level.
Keep input 2 pressed: dimming up.
When dimming up: dimmer stops at maximum value.
When dimming down: dimmer stops at minimum value.
Without memory
Briefly press input 2: load is switched on at maximum value.
The other operations are identical to those 'with memory'.
B. Meaning of LEDs during normal operation
The dimmer has a number of 'mode' LEDs and a number of 'input' LEDs (see fig.1).
EN
73