3.2. Electric data
Nom. voltage
Voltage range
Current consumption of generating warning signal
Current consumption failure indicator
Flash sequence
Frequency of main flash
Flash energy of main flash
Lifetime of flash tube
Duty cycle
Failure indication
3.3. Mechanical data
Degree of protection
Operating position
Protection class
Cable entry (prepared)
Clamping range of terminal
Weight
Material of base
Material of dome
Colours of dome
Type of dome
Aperture angle
PCB
Flash tube
3.4. Climatic data
Operating temperature
Storage temperature
Relative humidity
Applicability for outdoor use
3.5. Optical data
Fig. 5 Directional diagrams
Datei/ file name:085501931f D-E-F.doc
Orientation of
flash tube
Cd (Blondel & Rey)
19 / 44
24V DC
18V .. 30V
650 mA
65 mA
2-fold flash
1 Hz
7 Joule
After 8.000.000 flashes still approx. 70% light emission
100 %
max. 230V~ / 6A
min. 5V- / 10mA
IP 55 (EN 60529)
vertical
M20x1,5
for cables 6,5 mm ... 13,5 mm
0,08-2,5mm² (AWG28-12)
Direct mounting
0,7 Kg
ABS, black
Polycarbonat (PC)
Clear/ amber/ red/ green/ blue
Fresnel lens dome
vertical: 16°
horizontal: 360°
Immersed in protective lacquer
Fixed with a stainless steel clamp
- 30 °C .... + 55 °C
- 40 °C .... + 70°C
90%
suitable for field work
230 V AC
195 .. 253 V
145 mA
110 mA
II
Bracket mounting
1,2 Kg
Orientation of
flash tube
Cd (Blondel & Rey)
Zeichnungsnr./ Drwg-no.: 11516-42e