Extraction Air System Assembly - Kuppersbusch KMI8500.0 Mode D'emploi

Masquer les pouces Voir aussi pour KMI8500.0:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

Extraction air system assembly

The individual exhaust air components are inserted into one another
as shown in the illustration.
a
c
On point
The fl exible connection piece is used for a worktop thickness of 600 mm.
Please make sure that installation is as taut and crease-free as possible
by shortening excess material.
f
On point
Apply sealing tape to the plinth fan connecting pieces (f) before attaching
the adapter piece (d) to the plinth fan (e).
Important:
The components must all be fi rmly fastened as shown with the
adhesive tape enclosed after they have been attached.
b
c
d
e
Exhaust air duct components (inclusive):
a
b
c
e
Fan
f
Sealing tape
Plinth fi lter (optional):
g
Charcoal fi lter
GB
d
41

Publicité

Table des Matières
loading