Error code
01
OFF
my favourites
HOME
03 - 04
05
14
4219-450-07541 MANUAL GAG. CAD. PLUS EN-FR 120US rev_2.indd 33
Error Code Key
The list below reports the error codes that the display can show, their meanings
and how to solve the problem. If the indicated solutions are ineffective because
the display keeps showing the error code icon and the machine does not function
correctly, or if further error codes are displayed, please contact an authorised
x x
service centre or your local vendor..
The contact info is listed on www.gaggia.com and www.gaggia.it.
Problem
The coffee grinder is
clogged.
clean/setting
START/STOP
A problem occurred in the
brew group.
A problem occurred in the
water circuit.
The machine is
overheated.
Cause
The coffee outlet duct
is clogged.
The brew group is dirty
or not well lubricated.
The brew group is not
positioned correctly.
There is air in the water
circuit.
There may be multiple
causes.
Possible solution
Remove the power cord and remove the
brew group. Clean the coffee outlet duct
thoroughly using a spoon handle. Switch
the appliance on again.
Switch off the machine using the power
button. Remove the brew group and clean
it thoroughly. (Refer to the "Cleaning the
Brew Group" chapter)
Switch off the machine using the power
button. Remove the brew group and
reinsert it. Ensure that the brew group is
in the correct position before inserting it.
Refer to the "Reinserting the brew group"
chapter.
Remove and reinsert the tank in the
machine a couple of times. Make sure you
insert the tank correctly in the machine.
Check that the water tank seat is clean.
If you use an "INTENZA+" filter: pull out the
filter from the water tank and shake it to
remove all air from the filter. Then reinsert
the "INTENZA+" filter into the water tank.
Switch off the machine and switch it
on again after 30 minutes. Perform this
operation 2 or 3 times.
English
33
23/04/2020 09:31:34