6.9 Ground connection

CAUTION! The external equipotential
connections must be set up through the
eyelet on the outside of the product. Do not
use as a protective terminal.
Fig. 16
Protective earth connections, use suitable
cable sections: 4mm² (11AWG).
The ring terminal for external bonding connection is
provided by the manufacturer.
The equipotential earth connection is necessary for
carrying out additional connections required by law.
In any case a protection earthing conductor must be
applied to the inside connector (J1, 6.4 Connector
board description, page 18).
6.10 Connection compartment
closing
If you can't turn by hand the threaded
lid before the OR reaches the tube of the
connection compartment this means that
there are debris\dirt on the threads or that
the lid is misaligned. In this case there's
a serious danger of threads damaging.
Unscrew the lid and check the alignement
and/or clean the threads.
Never force the rotation of threaded lid
before the OR reaches the connection
compartment, otherwise thread damage
could occur.
22
If you suspect that any kind of thread
damaging has occurred, suspend the
installation. The device could be no longer
safe for the installation on a potentially
explosive atmosphere. In this case contact
VIDEOTEC technical support.
Verify that in the cap there isn't dirt or debris.
Lubricate the threaded part of the lid, of the
connection compartment and the seal with technical
vaseline oil lubricant.
Arrange the cables so that there is no interference
when closing the threaded lid of the connection
compartment.
Fig. 17
Screw by hand the threaded lid of the connection
compartment till the OR gasket reaches the tube.
Fig. 18
Fig. 19
MNVCMPXHD_1607_EN