SOMFY Elixo 500 3S io Manuel D'installation page 25

Masquer les pouces Voir aussi pour Elixo 500 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo 500 3S io
P14
Area lighting time delay
Values
0 to 60 value x 10 s = time delay value)
6: 60 s
Comments
If value 0 is selected, the area lighting goes out as soon
as the gate stops moving.
P15
Auxiliary output
Values
0: inactive
1: automatic: gate open indicator light
2: automatic: timed bistable
3: automatic: one-touch
4: controlled: bistable (ON-OFF)
5: controlled: one-touch
6: controlled: timed bistable
Comments
0: the auxiliary output is not taken into account.
1: the gate indicator light is off when the gate is closed,
flashing when the gate is moving and on when the
gate is open.
2: output activated when movement starts, during
movement then deactivated at the end of the time
delay programmed in parameter "P16".
3: one-touch at contact when movement starts.
4: operation changes as follows each time the memo-
rised button on the radio control point is pressed: ON,
OFF, ON, OFF...
5: one-touch at contact by pressing the memorised
button on the radio control point.
6: output activated by pressing the memorised button
on the radio control point then deactivated at the end
of the time delay programmed in parameter "P16".
P16
Auxiliary output time delay
Values
0 to 60 value x 10 s = time delay value)
6: 60 s
Comments
The auxiliary output time delay is only active if the value
selected for P15 is 2 or 6.
P19
Closing speed
P20
Opening speed
Values
1: slowest speed
to
10: fastest speed
Default value: 5
Warning
Comments
If parameters P19 or P20 are changed, the
installer must check that the obstacle detection
system complies with appendix A of standard EN
12 453. If necessary, install a safety edge and
check that compliance is obtained.
Failure to follow this instruction may result in
serious injury, e.g. due to crushing by the gate.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
P21
Closing slowdown zone
P22
Opening slowdown zone
Values
0: shortest slowdown zone
to
5: longest slowdown zone
Default value: 1
Warning
Comments
If parameters P21 or P22 are changed, the
installer must check that the obstacle detection
system complies with appendix A of standard EN
12 453. If necessary, install a safety edge and
check that compliance is obtained.
Failure to follow this instruction may result in
serious injury, e.g. due to crushing by the gate.
P25
Closing torque limitation
P26
Opening torque limitation
P27
Closing slowdown torque limitation
P28
Opening slowdown torque limitation
Values
1: minimum torque
to
10: maximum torque
Adjusted at the end of auto-programming
Warning
Comments
If parameters P25 to P32 are changed, the
installer must check that the obstacle detection
system complies with appendix A of standard EN
12 453. If necessary, install a safety edge and
check that compliance is obtained.
Failure to follow this instruction may result in
serious injury, e.g. due to crushing by the gate.
If the torque is too low, there may be erratic obstacle
detection.
If the torque is too high, the installation may not comply
with the standard.
P33
Obstacle detection sensitivity
Values
0: very low sensitivity
1: slightly sensitive
2: standard
3: very sensitive
Warning
Comments
If parameter P33 is changed, the installer must
check that the obstacle detection system com-
plies with appendix A of standard EN 12 453.If
necessary, install a safety edge and check that
compliance is obtained.
Failure to follow this instruction may result in
serious injury, e.g. due to crushing by the gate.
P37
Wired control inputs
Values
0: complete cycle mode - pedestrian cycle
1: opening mode - closing
Comments
0: terminal 11 input = complete cycle, terminal 9 input =
pedestrian cycle
1: terminal 9 input = opening only, terminal 11 input =
closing only
EN
10

Publicité

Table des Matières
loading