Short automatic closing time delay in pedestrian
P04
cycle
Values
0 to 30 (value x 10 s = time delay value)
2: 20 s
Comments
If value 0 is selected, the gate immediately closes
automatically.
Long automatic closing time delay in pedestrian
P05
cycle
Values
0 to 99 (value x 5 min. = time delay value)
0: 0 min
Comments
Value 0 must be selected if the short automatic closing
time delay in pedestrian cycle is active.
P06
Pedestrian opening amplitude
Values
1 to 9
2: 80 cm
Comments
1: minimum pedestrian opening
...
9: maximum pedestrian opening (approximately 80% of
the gate's total travel)
P07
Cell safety input
Values
0: inactive
1: active
2: active with autotest via test output
3: active with autotest via power supply switching
4: bus cells
Comments
0: the safety input is not taken into account.
1: safety device without autotest; it is essential to check
that it is operating correctly every 6 months.
2: the autotest is run on the device for each operating
cycle via the test output, reflex photocell application
with autotest.
3: the autotest is run on the device for each operating
cycle via power supply switching of the cell power
supply output (terminals 21 and 22).
4: bus cells application.
P08
Safety edge safety input
Values
0: inactive
1: active
2: active with autotest
Comments
0: the safety input is not taken into account.
1: safety device without autotest; it is essential to check
that it is operating correctly every 6 months.
2: the autotest is run on the device for each operating
cycle via the test output.
9
P09
Programmable safety input
Values
0: inactive
1: active
2: active with autotest via test output
3: active with autotest via power supply switching
Comments
0: the safety input is not taken into account.
1: safety device without autotest.
2: the autotest is run on the device for each operating
cycle via the test output.
3: the autotest is run on the device for each operating
cycle via power supply switching of the cell power
supply output (terminals 21 and 22).
P10
Programmable safety input - function
Values
0: active closing
1: active opening
2: active closing + ADMAP
3: all movement disabled
Comments
0: the programmable safety input is only active when
closing.
1: the programmable safety input is only active when
opening.
2: the programmable safety input is only active when
closing and, when activated, the gate cannot be
opened.
3: emergency stop application; if the programmable
safety input is activated, the gate cannot be moved.
P11
Programmable safety input - action
Values
0: stop
1: stop + partial reversal
2: stop + complete reversal
Comments
0: emergency stop application, compulsory if P10=3
disabled if a safety edge is connected to the pro-
grammable safety input
1: recommended for safety edge application
2: recommended for cell application
P12
Orange warning light
Values
0: no warning
1: with 2 s warning prior to movement
Comments
If the gate opens onto a public path, the "with warning"
configuration must be selected: P12=1.
P13
Area lighting output
Values
0: inactive
1: controlled operation
2: automatic + controlled operation
Comments
0: the area lighting output is not taken into account.
1: the area lighting is remotely controlled.
2: the area lighting is remotely controlled when the gate
is stationary + the area lighting comes on automati-
cally when the gate is moving, and remains on when
it stops moving for the duration of the time delay
programmed in parameter "P14".
P13=2 is compulsory for operation in automatic
mode.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.