Super Finish 23i
3.3
TECHNICAL DATA
Voltage :
Fuses :
Unit connecting line :
Max. current consumption:
Degree of protection :
Rated input of device:
Max. operating pressure :
Max. volume flow :
Volume flow at 12 MPa
(120 bar) with water :
Max. temperature of the
coating material :
Max. viscosity :
Empty weight
Model including carriage:
Model on frame:
Hydraulic oil filling
quantity :
Hydraulics housing
Gears
Max. vibration at the spraygun : lower than 2.5 m/s²
Max. sound pressure level:
*Place of measurement: 1 m distance from unit and 1.60
m above floor, 12 MPa (120 bar) operating pressure,
reverberant floor
230 V AC, 50 Hz
16 A time-lag
6 m long, 3 x 1.5 mm²
7.4 A
IP 54
1.3 kW
25 MPa (250 bar)
2.6 l/min
2.3 l/min
43 °C
20,000 mPas
29 kg
24 kg
1.15 liter
0.05 liter
74 dB (A)*
4
STARTUP
4.1
GUN
1. Screw either the whip hose (1 for injection work) or the
nozzle holder with nozzle (2 for spray work) to the gun.
Before any injection work, remove the filter
that is premounted in the gun, as described
below, to prevent it from becoming blocked.
2. Pull the protective bracket (3) forwards.
3. Screw the grip (4) out of the gun housing. Pull out the in-
sertion filter (5).
4. Screw the grip (4) into the gun housing and tighten it.
5. Latch in the protective bracket (3).
1
2
3
DESCRIPTION OF UNIT
5
4
35