Description of unit

3.4 Technical data

Voltage
:
Fuse protection
:
Unit connection line
:
Socket on unit
:
Max. connection
:
Type of protection
:
Capacity
: 0.96 kW
Max. operating pressure
:
Max. volume flow
: 2.0 l/min
Volume flow at 120 bar
(12 MPa) with water
: 1.7 l/min
Max. size of tip
: 0.021 inch
Max. temperature of
the coating material
:
Max. viscosity
:
Net weight
: 26 kg
Hydraulic filling quantity
:
Max. acoustic pressure level :
* Place of measuring: 1 m in distance from the unit and 1.6 m
above the floor, 120 bar (12 MPa) operating
pressure, reverberant floor
3.5 Transport

Super Finish 23

Push or pull unit.
Loosen terminal sleeves (fig. 7, item 1) on the shaft (L
open). Extract shaft to the desired length.
Tighten terminal sleeves again by hand (R closed).
1
Super Finish 21 • 23
All manuals and user guides at all-guides.com
Super Finish
Super Finish
21
23
230 Volt~, 50 Hz
220 Volt~,60 Hz
110 Volt~, 50 Hz
16 A slow-blow
6 m long, 3 x 1.5 mm
2
230 Volt ~, 50 Hz
220 Volt~, 60 Hz
110 Volt~, 50 Hz
1000 Watt
400 Watt (110 Volt~, 50 Hz)
IP 44
1.3 kW
250 bar (25 MPa)
2.4 l/min
3.0 l/min
(220 Volt~, 60 Hz)
2 l/min
2.6 l/min
(220 Volt~, 60 Hz)
0.023 inch
– 0.53 mm
– 0.58 mm
0.027 inch
– 0.69 mm
(220 Volt~, 60 Hz)
43°C
25.000 mPa·s
31 kg
0.9 litre, ESSO NUTO H 22
74 dB (A)*
g
g
Transport in vehicle
Super Finish 23
Unroll high-pressure hose and lay it over the shaft.
Super Finish 21 and 23
Secure the unit by means of suitable fastening.

4. Starting operation

4.1 Unit with suction system

1.
Screw off dust protection cap (fig. 8, item 1).
2.
Pay attention to clean sealing areas on the
connections.
Pay attention to the fact that the red inlet (2) is in-
serted into the coating material inlet.
3.
Screw and tighten the union nut (3) on the suction
pipe (4) onto the coating material inlet (5) with the
accompanying spanner 41 mm.
4.
Screw the union nut (6) on the return pipe (7) onto
the connection (8).

4.2 Unit with upper hopper (5 litres)

1.
Screw off dust protection cap (fig. 9, item 1).
2.
Pay attention to clean sealing areas on the
connections.
Pay attention to the fact that the red inlet (2) is in-
serted into the coating material inlet.
3.
Screw the upper hopper (3) onto the coating ma-
terial inlet (4).
4.
Hang the return pipe (5) into the upper hopper.
5.
Screw the union nut (6) on the return pipe (5) onto
the connection (7).
Starting operation
1
5
2
3
4
8
6
7
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Super finish 23

Table des Matières