W 200
Problem
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose
18. Technical Data
Max. viscosity:
Power source:
Power consumption:
Atomizing output:
Max. flow rate:
Double insulation:
Cause
•
Coating material assembly
at air cap, nozzle or needle
•
Nozzle loose
•
Nozzle seal worn
•
Nozzle worn
•
Material volume too large
•
Material volume adjusting
screw turned too far to the
right (+)
•
Nozzle contaminated
•
Viscosity of coating material
too high
•
Too little pressure build-up
in container
•
Air filter heavily soiled
•
Coating material in
container running out
•
Nozzle seal worn
•
Air filter heavily soiled
•
Too much coating material
applied
•
Viscosity of coating material
too low
•
Distance to the object too
large
•
Too much coating material
applied
•
Diaphragm soiled
•
Diaphragm defective
Technical Data
170 DIN-s
230 V, ~ 50 Hz
460 W
130 W
150 ml/min
Remedy
➞ Clean
➞ Union nut tighten
➞ Change
➞ Change
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean
➞ Dilute further
➞ Tighten container
➞ Change
➞ Refill
➞ Replace
➞ Change
➞ Turn material volume
adjusting screw to the left (-)
➞ Reduce distance
➞ Turn material volume
adjusting screw to the left (-)
➞ Clean the diaphragm
➞ Replace the diaphragm
GB