Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

W 200
Problem
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose

18. Technical Data

Max. viscosity:
Power source:
Power consumption:
Atomizing output:
Max. flow rate:
Double insulation:
Cause
Coating material assembly
at air cap, nozzle or needle
Nozzle loose
Nozzle seal worn
Nozzle worn
Material volume too large
Material volume adjusting
screw turned too far to the
right (+)
Nozzle contaminated
Viscosity of coating material
too high
Too little pressure build-up
in container
Air filter heavily soiled
Coating material in
container running out
Nozzle seal worn
Air filter heavily soiled
Too much coating material
applied
Viscosity of coating material
too low
Distance to the object too
large
Too much coating material
applied
Diaphragm soiled
Diaphragm defective
Technical Data
170 DIN-s
230 V, ~ 50 Hz
460 W
130 W
150 ml/min
Remedy
➞ Clean
➞ Union nut tighten
➞ Change
➞ Change
➞ Turn material volume
adjusting screw to the
left (-)
➞ Clean
➞ Dilute further
➞ Tighten container
➞ Change
➞ Refill
➞ Replace
➞ Change
➞ Turn material volume
adjusting screw to the left (-)
➞ Reduce distance
➞ Turn material volume
adjusting screw to the left (-)
➞ Clean the diaphragm
➞ Replace the diaphragm
GB
25

Publicité

Table des Matières
loading

Table des Matières