Super Finish 23i
8
CLEANING THE UNIT
A clean state is the best method of ensuring operation with-
out problems. After you have finished work, clean the unit.
Under no circumstances may coating material rests dry and
harden in the unit. The cleaning agent used for cleaning (only
with a flash point above 21 °C) must be suitable for the coat-
ing material used.
Warm water improves the cleaning effect in
the case of water-dilutable coating materials.
For spray work:
Secure the spray gun, refer to the operating
manual of the spray gun. Remove and clean
the tip.
1. Open the discharge tap.
2. Set ON/OFF switch to ON.
3. Turn the pressure control valve back in order to set a mini-
mal pressure.
4. Close the discharge tap.
5. Hold the gun or material ball cock/whip hose in an open
bucket. Pull the trigger on the gun or open the material
ball cock to pump any leftover materials out of the hopper
and out of the high-pressure hose (if appropriate, increase
the pressure at the pressure control valve slowly in order
to obtain a higher material flow).
The container must be earthed in case of
coating materials which contain solvents.
Caution! Do not pump in a container with
small opening (bunghole)!
See safety regulations.
6. Release the trigger on the gun or close the material ball
cock.
7. Fill up hopper with suitable cleaning agent.
8. Open the discharge tap .
9. Pre-clean the hopper and filter with a brush.
10. Pump suitable cleaning agent in the circuit for several
minutes.
11. Close the discharge tap
12. Hold the gun or material ball cock/whip hose in an open
bucket. Pull the trigger on the gun or open the material
ball cock to pump the cleaning agent out of the hopper.
Do this by pulling and releasing the trigger on the gun
several times/opening and closing the material ball cock.
13. Put fresh cleaning agent into the hopper and the repeat
the procedure described above 1 or 2 times.
14. Switch off unit
15. Open the discharge tap .
DISPLAYS AT THE UNIT / CLEANING THE UNIT
8.1
CLEANING THE UNIT FROM THE OUTSIDE
First unplug the power plug from the outlet.
Danger of short-circuits caused by water
ingression! Never spray down the unit with
high-pressure or high-pressure steam clean-
ers.
Do not put the high-pressure hose into sol-
vents. Use only a wet cloth to wipe down the
outside of the hose.
Wipe down unit externally with a cloth which has been im-
mersed in a suitable cleaning agent.
8.2
SUCTION FILTER
Clean filters always ensure maximum volume,
constant spray pressure and problem-free
functioning of the unit.
1. Release screws with a screwdriver (Item 2).
2. Lift and remove filter disk with a screwdriver
3. Clean or replace the filter disk.
Carry out cleaning with a hard brush and a corresponding
cleaning agent.
2
1
39