Outlet Valve; Pressure Control Valve - WAGNER Super Finish 23i Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
10.3

OUTLET VALVE

1. Use a 22 mm wrench to screw the outlet valve from the
paint section.
2. Carefully pull of the clasp (1) using the enclosed screw-
driver. The compression spring (2) presses ball (4) and
valve seat (5) out.
3. Clean or replace the components.
4. Check the O-ring (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(5) and seal (6), refer to figure.
6
5
42
5
3
6
3 2
7
4
1
10.4

PRESSURE CONTROL VALVE

Only have the pressure control valve (1) re-
placed by the customer service.
The max. operating pressure has to be reset
by the customer service.
1
Super Finish 23i

Publicité

Table des Matières
loading

Table des Matières